9261 Ravenna Rd., Suite B-12
Twinsburg, Ohio  44087
216-831-6600  •  FAX: 216-831-6618
  
Home Battery Basics & Sulfation Advanced Desulfation Technology Process Control Approach Applications About Us Contact Us
Canadus Advanced Desulfation Technology
By pulsing current at very high frequency and high amplitude, Canadus Advanced Desulfation Technology overcomes the activation energy necessary to destabilize lead sulfate. Sulfuric acid is re-formed, bringing the battery back to “like new” condition.

The following series of five photomicrographs, all shown at 550X magnification, illustrates the conversion of a fresh, active battery plate to a heavily sulfated inactive plate, and its transformation back to an active plate after using Canadus Advanced Desulfation Technology.

For detailed explanations of how a battery works and sulfation click here.

Figure 1 shows an active, new lead sponge battery plate.
click image to enlarge

Figure 2 shows a battery plate that has been coated by dense, hardened, crystalline lead sulfate. Notice that no active lead sponge is visible.
click image to enlarge

Figure 3 shows the partial recovery of a heavily sulfated plate following Canadus use. The size of the lead sulfate crystals is decreased, and the crystals are pitted as they are destroyed.
click image to enlarge

Figure 4 shows the final recovery of the plate to active sponge lead.
click image to enlarge

For More Information

For detailed information and specifications on Canadus battery energizers, e-mail us at
info@canadus.com or call
216-831-6600.
  Sunday, September 5, 2010     Advanced Desulfation Technology  
Home   |   Battery Basics & Sulfation   |   Advanced Desulfation Technology   |   Process Control Approach   |   Applications   |   About Us   |   Contact Us
© 1998-2010 Canadus Power Systems, LLC.  All rights reserved.   Trademarks & Copyrights Privacy Policies Site Map